Does the area experience wet/dry cycles or consistent moisture?
|
Is it suitable for manned entry?
|
Is it suitable for manned entry?
|
Do you have multiple leaks or isolated leaks?
|
Do you have multiple leaks or isolated leaks?
|
Using Acrylic or Urethane Grout?
|
Is the wall/structure above or below grade (ground level)?
|
Is the wall/structure above or below grade (ground level)?
|
Using Acrylic or Urethane Grout?
|
High water flow or low water flow?
|
Do you have a dual component or single component pump?
|
Manual (EGP) Method or Injection Method?
|
High water flow or low water flow?
|
Will you use a pump (recommended) or a cartridge?
|
Manual (EGP) Method or Injection Method?
|
Will you use a pump (recommended) or a cartridge?
|
Do you want a flexible foam to fill the crack or a rigid foam on the back of the structure?
|
Do you have a dual component or single component pump?
|
Contractor tips: Each project is unique. Call Avanti for ideas on how to slow high flow situations before you begin grouting. Do you have a dual component or single component pump?
|
Manual (EGP) Method or Injection Method?
|
Will you use a pump (recommended) or a cartridge?
|
Do you want a flexible foam to fill the crack or a rigid foam on the back of the structure?
|
Suggested Action/Information Probe Grouting with AV-275 (with catalyst AV-276). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To watch video click HERE. |
Suggested Action/Information Probe Grouting with AV-100 or AV-118. Typically needed: AV-101 and either AV-102 or AV-103, Proper PPE, probe(s) for delivering grout to desired depth. Dual component pump, storage tanks, & other equipment must be stainless steel or plastic. To watch video click HERE. |
Suggested Action/Information V-PAT Technique: Use AV-248LV (with catalyst AV-249LV) Typically needed: Airless paint sprayer (Graco 490 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information Curtain Grouting with AV-275 (with catalyst AV-276). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To watch video click HERE. |
Suggested Action/Information Curtain Grouting with AV-275 (with catalyst AV-276). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To watch video click HERE. |
Suggested Action/Information No Information available. |
Suggested Action/Information V-PAT Technique: Use AV-248LV (with catalyst AV-249LV) Typically needed: Airless paint sprayer (Graco 490 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information Contractor tips: Each project is unique. Call Avanti for ideas on how to slow high flow situations before you begin grouting. Curtain Grouting with AV-275 (with catalyst AV-276) or AV-290 (AV-290 requires a dual component pump and static mixing nozzle). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To watch video click HERE. |
Suggested Action/Information V-PAT Technique: Use AV-248LV (with catalyst AV-249LV) Typically needed: Airless paint sprayer (Graco 490 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information V-PAT Technique: Use AV-248LV (with catalyst AV-249LV) Typically needed: Airless paint sprayer (Graco 490 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information No Information available. |
Suggested Action/Information Inject AV-290 resin into the soil with rigid hydrophobic cartridge. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To see Curtain Grouting video click HERE. |
Suggested Action/Information Curtain Grouting with AV-100 or AV-118. Typically needed: AV-101 and either AV-102 or AV-103, Proper PPE, probe(s) for delivering grout to desired depth. Dual component pump, storage tanks, & other equipment must be stainless steel or plastic. To watch video click HERE. |
Suggested Action/Information Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component multi ratio pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting video click HERE. |
Suggested Action/Information Curtain Grouting with AV-278 (with catalyst AV-279). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see Curtain Grouting video click HERE. |
Suggested Action/Information Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting video click HERE. |
Suggested Action/Information Curtain Grouting with AV-278 (with catalyst AV-279). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see Curtain Grouting video click HERE. |
Suggested Action/Information The crack/joint must be wide enough to pack with "rope." EGP Method using AV-202. Typically needed: Oakum or Resin Rod, Proper PPE. To open EGP Brochure click HERE. To watch video click HERE. |
Suggested Action/Information V-PAT Technique: Thick cracks (AV-202*); Medium Cracks (AV-333*, AV-330*, AV-202-LV), Thin Cracks (AV-315). * = Certified for use with potable water. Typically needed: Airless paint sprayer (Graco 490 or similar), resin injectors (EZ-1s or similar), hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information Crack Injection with flexible hydrophilic cartridge. Thick cracks (AV-202*); Medium Cracks (AV-333*, AV-330*, AV-202-LV), Thin Cracks (AV-315). * = Certified for use with potable water. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To open V-PAT Brochure click HERE. To watch video click HERE. |
Suggested Action/Information Inject AV-290 resin into the soil with rigid hydrophobic cartridge. Typically needed: resin cartridges, single component gun, hammer drill, Proper PPE. To watch video click HERE. |
Suggested Action/Information Curtain Grouting with AV-254 or AV-350. Typically needed: Dual component pump, AV-208 Technical-Grade Acetone, AV-284 Pump Wash. To see Curtain Grouting video click HERE. |
Suggested Action/Information Probe Grouting with AV-278 (with catalyst AV-279). Typically needed: Airless paint sprayer pump (Graco 490 or similar), injectors (EZ-1s or similar), AV-208 Technical-Grade Acetone, AV-284 Pump Wash, Jiffy Mixer, Proper PPE. To see Curtain Grouting video click HERE. |